<LOGO>
FM Transmitter Measurement Report
Created: 2026-02-28 22-54-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 4/5, 40 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 69 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 59 kHz 6159 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,5 dBr 3,95 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 22:54, 28.02.2026
RT
"YleX Throwback: Womma (u) "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 59 kHz MIN: 12 kHz % above 76 kHz: 0,0000 Acquired: 2026/02/28 22.53.17 Total samples: 6159 Equivalent time: 0:05:07 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 5,1 dBr MIN: 2,5 dBr AVE: 3,95 dBr % above 12,2 dBr: 0,0 Last value: 3,7 dBr (2026/02/28 22.53.16) 22.40 22.42 22.44 22.46 22.48 22.50 22.52 0 2 4 6 Pm [dBr]